Desktop Fluorescence Spectrometer |
|
|
|
 |
|
|
|
Features:
-
High sensitivity and
accuracy
FluSys-405:< 0.5nm
FluSys-532:< 0.5nm
-
Customized wavelength
range and resolution
-
Fit various applications
-
Support download for
Spectral Analysis 5.0
|
Applications:
|
|
|
■
Basic
components |
|
|
-
FPB-405/ 532
Fluorescence
probe
-
405/
532
fiber coupled laser
-
Fiber spectrometer: Aurora4000
-
PC
data processing unit
-
Man-machine Interface
|
|
|
■
Specifications |
|
|
|
Laser |
|
Wavelength (nm) |
405±5
(other wavelengths can be
customized) |
532±1
(other wavelengths can be
customized) |
|
Mode |
Near TEM00 |
TEM00 |
|
Power stability (pk-pk, 4 hours) |
<1%,3%,5% |
<1%,3%,5% |
|
Operating mode |
CW |
CW |
|
Warm-up time (minutes) |
<5 |
<10 |
|
Operating temperature (℃) |
10-35 |
10-35 |
|
Expected lifetime (hours) |
10000 |
10000 |
|
Warranty |
1 year |
1 year |
|
|
|
|
Spectrometer |
|
Wavelength range |
405-850 nm
(spectrometer wavelength
range and resolution can be
customized) |
532-1100 nm
(spectrometer wavelength
range and resolution can be
customized) |
|
Optical resolution
(nm) |
<0.5 nm FWHM |
|
Pixels(pixels) |
3648 |
|
Pixels size |
8
μmx
200
μm |
|
Dimensions (mm) |
149x 105x 46 |
|
Weight (g) |
840 |
|
Signal-to-noise ratio |
300:1 |
|
Integration time |
4ms-10s |
|
Power consumption |
450 mA@ 5V DC |
|
Data transfer speed |
Full scans into memory every 4
milliseconds with USB 2.0
Full scans into memory every 18
milliseconds with USB 1.1
|
|
Inputs/outputs |
5 inputs and 5 outputs
(opto-isolator inputs/outputs) |
|
Analog channels |
One 12 analog input one 12 analog
output |
|
Connector |
30pin |
|
|
|
|
Fluorescence Probe |
|
Excitation wavelength
(nm) |
405
(Spectrum linewidth ~1 nm) |
532
(Spectrum linewidth ~1 nm) |
|
Probe focus length (mm) |
7.5 |
|
Main material
of probe |
Black anodised aluminium,
111*38*14.8mm head 38mm
long |
|
Fiber configuration |
Two
single fiber (100 um excitation fiber,
200 um receiving optical fiber) N.A.=0.22,
SMA905 connector, PVC/metal sheath; 1 m
length |
|
Filter effect |
Can be
completely filtered out of the stray
light received, and eliminate the quartz
fiber generated background scattering
(O.D.> 5 @ laser wavelength) |
|
Working
temperature (℃) |
0-40 |
|
Connection port |
SMA 905
connector |
|
|
|
|
Software |
|
Optical spectrum analysis |
Spectrum Analysis Software |
|
Operating system |
Windows XP/ Win7 (32 bits
or 64 bits) |
|
|
|
|
■
Characteristic |
|
|
-
Dimensions: 420x 272x 160 mm
-
405/ 532nm excitation laser source
with adjustable and stable
power
-
Simple, fast measurement and
easy operation
-
flexible and stable
sampling, various forms in
analyzing samples
-
external power supply
(charging), with
vehicle-mounted charger
-
dustproof, waterproof,
anti-vibration, Anti-glare
interference in wild
environment usage
|
|
■
Accessories |
|
|